TEC - 110kW 3ph 4 Pole IE1 Efficiency AC Motor in a Compact 280 frame for 400V 3 phase supply.
Totally enclosed to IP55.
Includes shaft mounted cooling fan.
Use with a suitable AC Frequency Inverter Drive over a wide speed control range with suitable de-rating at the lower speeds.
Fixed mains supply output is 110kW (150HP) x 1470RPM at 400V x 50Hz 3ph.
Full Load Current - 189A at 400V.
Overload - 150% x 60seconds.
Efficiency is 93% at full load.
Power Factor is 0.9 when mains connected at 50Hz.
Terminal Box Position: Right Hand Side when viewed from the Drive End
Set terminal box links 'three a-breast' for 400V 'Delta' connection.
Set terminal box links ‘two at one side’ for 660V 'Star' connection.
666mm Wide x 918mm Long x 559mm high overall in its IP55 enclosure.
Foot mount on 24mm holes at 457mm wide x 368mm centres 190mm back from shaft shoulder.
Weight is 660kg.
Roller Bearing at Drive End
Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Full part number is -110.043TECCB3-280-S2+TBOXRHS
For Variable Speed use…
Part Time Output when Inverter powered is...
600Nm - 110kW (150HP) x 1764RPM at 60Hz
707Nm - 110kW (150HP) x 1470RPM at 50Hz
707Nm - 55kW (75HP) x 735RPM at 25Hz
707Nm - 11kW (15HP) x 147RPM at 5Hz
Continuous Output when Inverter powered is...
600Nm - 110kW (150HP) x 1764RPM at 60Hz
707Nm - 110kW (150HP) x 1470RPM at 50Hz
601Nm - 46.8kW (62.7HP) x 735RPM at 25Hz
354Nm - 5.5kW (7.5HP) x 147RPM at 5Hz
Download the full Technical Catalogue from the link below...
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.