TEC Electric - 3kW 3ph 4 Pole High Efficiency Foot and Flange Mounting (B35) 100L1 Frame AC Motor for 230V or 400V 3 phase supply. Inverter Rated for use with a Variable Frequency Inverter Drive having 1ph or 3ph input and 3ph output. Complete with 1024ppr Encoder and Axial Force Ventilation Fan.
Fixed mains supply output: 3kW (4HP) x 1440RPM at 230V or 400V x 50Hz 3ph.
Inverter Supply Output: 20:1 Speed Control range from 144RPM to 2880RPM for 5Hz to 70Hz control, with suitable de-rating at the lower speeds.
Also fitted with a 1024ppr HTL encoder
Full Load Current - 10.96A at 230V, or 6.33A at 400V.
Power Factor is 0.8 when mains connected at 50Hz.
Efficiency is 85.5%
198mm Wide x 477mm Long x 252mm high overall in its IP55 enclosure.
Foot mount on 10mm holes at 160mm wide x 140mm centres 63mm back from the shaft shoulder.
Flange mount on 15mm holes at 215mm PCD with 180mm diameter spigot in the 250mm diameter flange.
Shaft is 28mm dia x 60mm with 8mm wide key.
Weight is 32kg.
Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Manufacturer Part Number is 3.043TECAB35-IE2-ENC/FVU
For Variable Speed use:-
Part Time Output when Inverter powered is...
9.95Nm - 3kW ( 4.02HP) x 2880 RPM at 100 Hz
19.90Nm - 3kW ( 4.02HP) x 1440 RPM at 50 Hz
19.90Nm -1.5kW ( 2.01HP) x 720 RPM at 25 Hz
19.90Nm - 0.3kW (0.40HP) x 144 RPM at 5 Hz
Continuous Output when Inverter powered is...
14.2Nm -3kW ( 4.02HP) x 2016 RPM at 70 Hz
19.90Nm -3kW ( 4.02HP) x 1440 RPM at 50 Hz
16.92Nm - 1.28kW ( 1.71HP) x 720 RPM at 25 Hz
9.95Nm - 0.15kW (0.20HP) x 144 RPM at 5 Hz
Download the full Manual and Dimensions from the links below:-
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.