TEC 1.5kW (2HP) x 1420RPM/2160RPM AC Vector Motor, IP55, B14, 90 Frame

1.543TECAB14-FORCEVENT-90A230/1/50-ENC2048 (TECA2-90L-4-B14-FV-ENC2048)

Order Code: 33760
Obsolete Product
This item is now obsolete. Alternatives may be available - see linked products below.

Brand: TEC Electric Motors, Range: TECA Three Phase IE2 Aluminium

TEC Electric - 1.5kW 3ph 4 Pole High Efficiency Flange Mounting (B14 Face Mounting) 90L Frame AC Vector Motor for 230V or 400V 3 phase supply.  Inverter Rated for use with a Variable Frequency Inverter Drive having 1ph or 3ph input and 3ph output, or a fixed frequency mains supply at 50Hz..  Complete with axial force cooling fan (requiring separate 400V supply) and 2048ppr encoder fitted inside extended rear cowl. (plug and sockets supplied as standard)
Frame size TECA2-90L-4-B5-FV-ENC

Fixed mains supply output: 1.5kW (2HP) x 1420RPM at 230V or 400V x 50Hz 3ph.
Inverter Supply Use:  15:1 Speed Control range - 144RPM to 2160RPM for 5Hz to 75Hz, with suitable de-rating at the lower speeds.  Very Low Speed, down to 1Hz are possible with correct setting of the 'Boost' parameter (see the 'How To' Blog above).

Full Load Current - 5.73A at 230V, or 3.31A at 400V.
Power Factor is 0.79 when mains connected at 50Hz.
Efficiency is 82.8%

Forced Ventilation Fan: Single Phase 230/50Hz (0.14A 20W)  Note: 3 Phase 230/400V/50HZ option avaiable on request

175mm Wide x 427mm Long (approx) x 229mm high overall in its IP55 enclosure.
Mounting: Face mount on 4 x M8 tapped holes at 115mm PCD with 95mm diameter register in the 140mm diameter flange.
Shaft is 24mm dia x 50mm with 8mm wide key.
Weight is 20kg.

Rated at 40C Ambient. 
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Part number is - 1.543TECAB14-FORCEVENT-90A230/1/50-ENC2048

Download the full Manual and Dimensions from the links below:-

From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.