Control Techniques Commander M201 series AC Inverter for 30kW (40HP) 400V 3ph motor to 66A at High Overload or 37kW (50HP) to 79A when Fan/Pump rated, in either VxF or sensorless vector control. Converts fixed frequency 400V three phase input to variable frequency 400V three phase for a standard AC Induction motor.
Size 7: 270mm wide x 280mm deep x 557mm high; IP20
Mounting via 4 x 9mm diameter holes at rear on 220mm x 538mm centres
Weight: 28kg.
Overload: 150% x 60 seconds
Speed Control Range: 0-550Hz
Dynamic Braking (DBr): Internal Brake Switch fitted. (does not have to be used; available if required)
100% duty into 7.5 Ohm, maximum 10 Ohm external resistor (not supplied). See linked products below for compatible resistor.
Fixed keypad with Potentiometer for local speed control.
2 Analogue Inputs, 4 Digital Inputs, 1 Analogue Output, 1 Digital Input/Output, 1 Relay Contact (normally open). 1 Option Card Slot. Can be commissioned via PC using free Connect software and optional RS485 communications adapter and cable (see linked products below).
STO: Not available on this model.
Onboard PLC included. Programmable via PC using free CODESYS-based Machine Control Studio software and optional RS485 adapter and cable.
Input Current: 74A
Input Voltage: 380V-480V Three Phase ±10% at 50-60Hz ±5%
Earth Leakage for EMC: 56mA at 50Hz
EMC Compliance: IEC EN 61800-3 Category C3 (Industrial) for cable lengths to 100m.
Cubicle mount.
Ambient operating temperature to 40°C.
Ventilation space in front: [not specified], above and below: 100mm, at sides: 30mm (between drives).
Heat Loss at max output: 812W (High Overload); 999W (Fan/Pump) (at rated ambient temperature and default switching frequency).
Manufacturer part number is M201-07400660. Replaces Commander SK4401
Previously marketed under the Emerson brand.
Download the Unidrive M200 Series Installation and Control guides from the links below:-