Vascat 0/446/446/277kW x 0/1168/2040/3200RPM Square Frame AC Vector Motor, foot mounting (B3) for 400V 3 phase supply.
315 Frame, Force Ventilated from the Left side (IC06) to IP23.
Includes Double Shaft, 2 x Provision for T12 5kNm Torque Flange + 1 x Blocking Device, 1024ppr HTL Encoder, Force Cooling fan, intake filter, Ball bearing at DE, insulated bearings, Shaft Grounding Ring, Thermistors and bearing temperature probes.
Use with a Closed Loop AC Vector Drive with 3.1kHz minimum switching frequency, having the encoder board option for full closed loop vector control.
Motoring:-
Power Output: 0/446/446/277kW.
Overload: 150% to S6 (40%) below 1370RPM, then tapering off to 100% at maximum speed (set a tapered Current limit to prevent the motor slipping out of sync at the higher speeds).
Base Speed: 1168RPM.
Maximum Speed at Full Output: 2040RPM.
Maximum Speed at Reduced Output: 3200RPM.
Torque to Base Speed: 3650Nm.
Torque at Maximum Speed: 827Nm.
Full Load Current: 803A.
Voltage: 400V 3 Phase.
Supply Frequency: 59/162Hz at Base/Maximum Speed.
Magnetising Current: 299A.
Absorbing:-
Power: 0/471/471/310kW.
Overload: 150% to S6 (40%) below 1440RPM, then tapering off to 100% at maximum speed (set a tapered Current limit to prevent the motor slipping out of sync at the higher speeds).
Base Speed: 1232RPM.
Maximum Speed at Full Output: 2150RPM.
Maximum Speed at Reduced Output: 3200RPM.
Torque to Base Speed: 3650Nm.
Torque at Maximum Speed: 925Nm.
Full Load Current: 803A.
Voltage: 400V 3 Phase.
Supply Frequency: 61/159Hz at Base/Maximum Speed.
Magnetising Current: 299A.
Dimensions: 694mm Wide Body (+ fan at 457mm) x 1375mm Long x 840mm high overall.
Mounting: Foot mount on 28mm slots at 416/508mm wide x 547mm centres, 216mm back from the shaft shoulder.
Weight: 1750kg.
Rotor Inertia: 9.68kgm2.
Shafts: Each 100mm diameter x 187.5mm from shoulder with HBM T 12 torque flanges and one blocking device.
Drive End Bearing: Ball Bearing for a direct connected load.
Bearing Protection: Insulated Bearings plus High Speed Bearing Current bypass brush fitted to NDE.
Balance: to Class 'B'.
Ambient Temperature: 40C at up to 1000m above sea level.
Cooling: Force Ventilation Fan with Intake Filter fitted at 4kW for 400V 3ph 50Hz supply at 7.4A.
Cooling Fan Position: Rear left side.
Terminal Box Position: Front on top
Over-Temperature Protection: Thermistors and bearing temperature probes included for use with Customers external protection device.
Encoder: ITD89H00 1024 H NI KR1 E 110 fitted .
Part number: MAC QT 315S C62 IP23 B3 OV21000631 LH + 35589
Download the MAC-QI-315S Dimension drawing and data sheets (2 pages) showing output curves from the links below: