Vascat 0/125/125/125kW (absorbing) x 0/265/653/3300RPM Square Frame AC Vector Motor, foot mounting (B3) for 400V 3 phase supply.
315 Frame, Force Ventilated (IC06) to IP23.
Includes force cooling fan, intake filter, Ball bearing at DE, insulated bearings, Shft Grounding Ring, Thermistors, bearing temperature probes and 2048ppr x 15V HTL Encoder.
Use with Closed Loop AC Vector Drives with 3.25Hz minimum switching frequency, having the encoder board option fitted for full closed loop vector control.
Continuous Absorbtion: 0/125/125/125kW.
Overload: 150% to S6 (40%) below 780RPM, then tapering off to 100% at maximum speed (set a tapered Current limit to prevent the motor slipping out of sync at the higher speeds).
Base Speed: 653RPM.
Maximum Speed at Full Output: 3300RPM.
Torque to Base Speed: 4505Nm (5200Nm maximum available continuous).
Torque at Maximum Speed: 362Nm.
Full Load Current: 532A (583A continuous at maximum available torque).
Voltage: 400V 3 Phase.
Supply Frequency: 32/162Hz at Base/Maximum Speed.
Magnetising Current: 197A.
Dimensions: 630mm Wide Body x 1363mm Long x 1225mm high overall (refer to the drawing linked below).
Mounting: Foot mount on 28mm holes at 416/508mm wide x 655mm centres, 216mm back from the shaft shoulder.
Weight: 2095kg.
Rotor Inertia: 11.78kgm2.
Shaft: 120mm diameter x 210mm from shoulder without keyway.
Drive End Bearing: Ball Bearing for a direct connected load.
Bearing Protection: Insulated Bearings and High Speed Bearing Current bypass brush fitted to DE.
Ambient Temperature: 40C at up to 1000m above sea level.
Cooling: Force Ventilation Fan with Intake Filter fitted at 4kW for 400V 3ph 50Hz supply at 7.6A.
Over-Temperature Protection: Thermistors and bearing temperature probes included for use with Customers external protection componnts.
Part number: MAC-QT315M-D61-B3-OV18000537-2186. (MACQT315MD61-B3)