Siemens SINAMICS G120 Control Unit with Encoder Feedback model CU250S-2PN. A key component of the modular SINAMICS G120 range, the Control Unit must be fitted to a compatible Power Module to form a complete Inverter Drive.
• PM240 (3 AC 400 V for standard applications with dynamic
braking)
• PM240-2 (3 AC 400 V for standard applications with
dynamic braking, 2nd generation)
in degree of protection IP20 and Push Through (PT)
• PM340 (1 AC 200 V with dynamic braking)
• PM250 (3 AC 400 V with energy recovery)
• PM260 (3 AC 690 V with energy recovery),
Size: 73mm Wide × 178mm High × 55mm Deep
Weight: 0.52kg
Operation: VxF, Sensorless Flux Vector, Full closed-loop Flux Vector
Analogue Inputs: 2
Analogue Outputs: 2
Digital Inputs: 11 Fixed(isolated) , 4 can be switched over (Non isolated)
Digital/Relay Outputs: 3 Fixed relay, 4 can be switched over Transistor
Pulse Input : Max 32 kHz
Encoder Feedback Terminals: HTL, TTL 500kHz max (SSI 1 MHz baud rate) : Resolver • Ratio ü = 0.3 … 0.7
Motor Temperature Terminals:PTC,KTY84
Slot for memory card (MMC)
1 x USB
Fieldbus: PROFINET
Fail-safe digital input 1 (DI 4 and DI 5) • If you have enabled the basic safety functions, DI 4 and DI 5
form the fail-safe digital input.
• Maximum input voltage 30 V, 5.5 mA
• Response time:
– Typical: 5 ms + debounce time p9651
– Typical, if debounce time = 0: 6 ms
– Worst-case scenario: 15 ms + debounce time
– Worst case, if debounce time = 0: 16 ms
License is required for more than basic safety functions or for servo mode.
Part number is 6SL3246-0BA22-1FA0. Model number is CU250S-2PN
See manuals below