Parker SSD 591P Series 110A Single or Two Quadrant DC Thyristor (thyristor) Drive for 400V Supply with 110V or 230V Control supply. Converts a three phase AC supply to DC for speed and torque control of a DC motor.
Typical Motor output, up to 45kW (60HP) at 460V DC.
Keypad and analogue Tacho-generator feedback board are included.
Simple to set-up in Digital, fully-isolated Single or Two Quadrant form and ready to run from its Quick Set-Up settings.
Dimensions: Frame Size 2, 200mm Wide x 292mm Deep x 434mm High.
Terminals include:-
5 x Analogue Inputs (4 x Configurable).
3 x Analogue Outputs (2 x Configurable).
Tacho input (or internal AVF) Feedback.
10 x Digital inputs - 5 are Configurable including two as encoder inputs for a second or line encoder.
3 x Digital Outputs (all Configurable).
+ - 10V for Potentiometers.
Input Current: 91A for Armature + up to 10A for Field.
Input Voltage: 380V/415V/440V/460V three phase +-10% at 50/60Hz.
Input fuse: 160A or lower to suit input bridge at 15,000A2s
Use a choke in the supply at 50uH minimum.
Ambient Temperature: Rated at 40C.
Ventilation space above: 161mm.
Ventilation space below: 100mm.
Ventilation space at sides: 0mm.
Heat Loss: 354W at maximum output.
Mounting: Panel mount with M6 screw fixings on 418 x 140mm centres.
Part Number: 591P-53311020-P00-U4A0. Was - 591P-0110-500-0011-UK-AN-0-0-000, Exactly the same as Eurotherm Drives 591P-0110-500-0011-UK-AN-0-0-000.
Download the 590P Technical product Manual from the link below...