Parker SSD 890 Series AC Frequency Inverter for 4.0kW 230V 3 Ph motor to 16.5A or 5HP 230V 3ph motor. Suitable for a Standard AC Induction Motor in VxF, Sensorless Vector Control or Full Closed Loop Vector Control with an optional Speed Feedback Card. Also suitable to control a PM Brushless AC Servo Motor when fitted with an optional Feedback Card. (See Feedback Options below)
The 890CD is a modular Inverter designed for energy-saving or space-saving Common DC Bus applications. It requires an 890 Common DC Bus supply unit to function correctly, see products linked below.
Features: Advanced Performance including, Basic LINK VM function blocks: math functions, Boolean logic, timers, counters, One shots, threshold comparators, latches, plus: motion control firmware with added position loop, motion control function blocks, move incremental, move absolute, move home, line drive master ramp and section control, winder blocks (SPW, CPW), full function PID, state of machine and others.
Dimensions: Size B: 72.4mm Wide x 258.5mm Deep x 433.6mm High.
Enclosure Rating: IP20.
Weight: 5kg.
Overload: 150% x 60 seconds.
Speed Control Range: 0-1000Hz (VxF), 0-350Hz (Closed-loop Vector), 0-120Hz (Sensorless Vector).
Braking: not applicable, this is provided by the Common DC Bus supply unit.
Terminals: 4 Analogue Inputs, 7 Digital Inputs, 2 Analogue Outputs, 2 Digital Inputs/Outputs, 1 Relay Contact Set, USB port for Programming.
Safe Torque Off: to SIL3 or PLe level per EN ISO13849 and EN61800-5-2.
Input Current: 22.2A (Vector Mode).
Input Voltage: 320V DC supplied by 890 Common DC Bus Supply unit.
EMC Filters: to EN61800-3 2nd Environment (Industrial).
Mounting: Cubicle mount via 2 x holes at rear on 413.6mm centres, or onto 35mm DIN rail using fitting kit included.
Ambient: Rated 45°C.
Ventilation space in front: [Not Specified].
Ventilation space above and below: 150mm.
Ventilation space at sides: 0mm (drives can be mounted side by side).
Option Modules were originally supplied fitted to the 890CD, Modules are now supplied as additional items (Please see linked items below).
Additional option cards are required to achieve the variants given below:
Part Number Variation in block 4 (Legacy Part Variations in blocks 10): 1(E1), 3(EQ), 5(RE), 6(RR), 7(M1), L(LS) eg 890CD-531200B0-B00-1A300 (890CD/5/0002B/B/00/A/UK/00/00/EQ/00/00) was supplied with an Encoder Feedback Option card 8902-EQ-00 fitted.
Part Number Variation in block 4 (Legacy Part Variations in block 11): N(CB), C(CN), D(DN), H(IP), T(IM), P(PB), 7(M1), S(RS), K(CT), E(EP) eg 890CD-531200B0-B00-1A0P0 (890CD/5/0002B/B/00/A/UK/00/00/00/PB/00) was supplied with Profibus Communications Card 8903-PB-00 fitted
Part Number: 890CD-232165B0-000-1A000.
Model Number: 890CD/2/0016B.
Download the Parker 890 Installation Manual and 890 Common DC Bus Quick Start Guide from the links below:-