Schneider Altivar 212 (ATV212) series AC Inverter for 1.5kW (2HP) Three Phase 400V Centrifugal Fan or Pump in VxF or Sensorless Vector control to 3.7A. Converts fixed frequency Three Phase input to variable frequency Three Phase 400V.
**Special Price - Unit available from stock only**
Pump Control Features:-
Sleep and wake functions for Energy Management.
Ventilation and Air Conditioning (Fan) Control Features:-
Smoke purge. Damper control. Monitoring and measurement of energy consumption. Electricity and Service Hours meter. Energy-saving motor control algorithm.
Low Harmonics: Reduced Harmonics Technology significantly reduces harmonic currents by 60% or more without the use of additional harmonic reduction devices.
Size 1A: 107mm Wide x 150mm Deep x 143mm High (192mm High with cable clamp plate fitted). IP21.
Weight: 2kg.
Overload: 110% x 60 seconds
Speed Control Range: 0.5-200Hz
Braking: None.
2 Analogue Inputs, 1 Analogue Output, 3 Digital Inputs, 2 Relay Contact sets, RJ45 port for Graphic Display Terminal or Modbus RTU communications. Terminals for Modbus RTU, Metasys N2, Apogee P1 FLN, BACnet or LonWorks communications.
Input Current: 3.2A
Input Voltage: 380-480V Three Phase -15% +10% at 50-60Hz ±5%
EMC Filters: IEC 61800-3 category C2, C3 (Industrial and Domestic)
Wall mount in clean environment or cubicle mount.
Rated 40°C Ambient.
Ventilation space in front: 10mm.
Ventilation space above and below: 50mm.
Ventilation space at sides: 50mm (0mm with top vent cover removed).
Heat Loss at max output: 78W.
Mounting via 4 x 5mm diameter holes at rear on 93mm x 121.5mm centres.
Manufacturer part number is ATV212HU15N4. Previously sold under the Telemecanique brand. Replaces the Altivar ATV 21.
Download the Schneider Electric Altivar ATV 212 Installation Manual, Programming Manual and Quick Start Guide from the links below:-