Mitsubishi FR-A800 E Series AC Inverter for 250kW (335HP) 400V 3 Ph motor to 481A at high overload, or 315kW (420HP) to 610A when Fan/Pump rated. Operates in VxF, Sensorless Vector or Full Closed-loop Flux Vector (when the optional Encoder Feedback card is fitted). Simple set-up and ready to run from its default settings.
Dimensions: Size 10 680mm Wide x 380mm Deep x 1010mm High.
Enclosure Rating: IP00
Weight: 166kg
Overload: 150% x 60 seconds, 200% x 3 seconds at High Overload rating, or 110% x 60 seconds, 120% x 3 seconds when Fan/Pump Rated.
Speed Control Range: 0.5Hz to 400Hz.
Braking: None (option via external brake unit).
Terminal CA Equipped Model.
3 Analogue Inputs, 12 Digital Inputs, 2 Analogue Outputs, 5 Digital Outputs, 2 Relay Contact Sets, integrated PLC functions and RS485 Modbus-RTU,
Includes Built-in Ethernet Board (FR-A8ETH).
Control Logic - Source Version.
Circuit Board Coated (Conforming to IEC60721-3-3 3C2/3S2).
'Safe Torque Off' (STO) function to SIL 2.
Input Current: 481A at high overload or 610A when Fan/Pump rating set.
Input Voltage: 380V to 500V Three Phase +10% -15% at 50/60Hz ±5%
EMC Filters: to BSEN61800-3 for the 2nd Environment (Industrial).
Mounting: Cubicle mount via 6 x 12mm diameter holes at rear on 300/600mm x 984mm centres
Ambient Temperature: Rated -10° to 50°C (40° when Fan/Pump rated).
Ventilation space in front; 50mm
Ventilation space above and below: 200mm.
Ventilation space at sides: 100mm.
Includes a separate DC Reactor (Choke): Part number FR-HEL-H250K (Failure to fit will cause damage to drive).
Part Number: FR-A840-06100-E2-60 + FR-HEL-H250K (Replaces FR-A840-06100-2-60)