Your Cart is empty!
Condition: New with Warranty Brand: Danfoss, Range: VLT FC302
Danfoss FC-302 AC Frequency Inverter 1.5kW (2HP) for 3 Ph motors in VxF, Sensorless Flux Vector or Full Closed Loop Flux Vector control (when the optional encoder board is fitted). Converts fixed frequency three phase 400V input to variable frequency three phase 400V to control the speed of a standard AC Induction motor or permanent magnet synchronous motor. Frame Size A2: 268mm high x 90mm wide x 205mm deep. IP20. Weight: 4.9kg
Output Current: 4.1A for 380-440V, 3.4A for 440-500V. Overload - 160% x 60 seconds. Speed Control Range - 0/1000Hz. No Keypad Fitted. Braking: No brake switch fitted. MCA 120 Profinet option fitted.
2 x Analogue Inputs, 6 Digital Inputs, 1 Analogue outputs, 2 Digital/Pulse outputs, 2 Relay Outputs. 1 x Safe Torque Off Input, Category 3 to SIL2, SILCL2, performance level "d". Programmable from a PC via USB and free Danfoss MCT 10 software (see download link below). Input Current – 6.8A. Input Voltage - 380/500V three phase +-10% at 50/60Hz. EMC Compliant to Class A1/B (C1) Domestic Environment. Wall mount in clean environment or cubicle mount. Rated at 50C Ambient. Ventilation space above and below: 100mm. Ventilation space at sides: 15mm. Heat Loss at max output: 62W. Mounting – 5.5mm screw fixings on 90mm x 257mm centres.
Product Code: 131N8042
Full part number: FC-302P1K5T5E20H1XXXXXXSXXXXALBXCXXXXDX.
130B1107
Order code: 27939
1 in stock
2+ normally 3-5 days
130B1117
(LCP 102)
Order code: 26778
Delivery 2 weeks
We've sent you a message containing a confirmation link. Click the link to complete the process.