Control Techniques Commander C200 series AC Inverter for 15kW (20HP) 400V 3ph motor to 35A at High Overload or 18.5kW (25HP) to 38A when Fan/Pump rated, in either VxF or sensorless vector control. Converts fixed frequency 400V three phase input to variable frequency 400V three phase for a standard AC Induction motor.
Size 6: 210mm wide x 227mm deep x 391mm high; IP20
Mounting via 4 x 7mm diameter holes at rear on 196mm x 378mm centres
Weight: 14kg.
Overload: 150% x 60 seconds (Heavy Duty) or 110% for 165 seconds (Normal Duty) from start up.
Speed Control Range: 0-550Hz
Dynamic Braking (DBr): Internal Brake Switch fitted. (does not have to be used; available if required)
100% duty into 20 Ohm, minimum external resistor (not supplied). See linked products below for compatible resistor.
Fixed keypad, 2 Analogue Inputs, 4 Digital Inputs, 1 Analogue Output, 1 Digital Input/Output, 1 Relay Contact (normally open). 1 Option Card Slot. Can be commissioned via PC using free Connect software and optional RS485 communications adapter and cable (see linked products below).
STO: Not available on this model.
Onboard PLC included. Programmable via PC using free CODESYS-based Machine Control Studio software and optional RS485 adapter and cable.
Input Current: 36A
Input Voltage: 380V-480V Three Phase ±10% at 50-60Hz ±5%
EMC Compliance: IEC EN 61800-3 Category C3 (Industrial) for cable lengths to 10m.
Cubicle mount.
Ambient operating temperature to 40°C.
Ventilation space in front: [not specified], above and below: 100mm, at sides: 0mm (between drives).
Heat Loss at max output: 389W (at rated ambient temperature and default switching frequency).
5 Year Warranty: A 5 year warranty is available on this product. Registration is required please see linked file below for registration details.
Manufacturer part number is C200-06400350.
Download the CT Commander C200 Quick Start, Installation and Control guides from the links below for futher details:-