ABB ACS355 AC Frequency Inverter for 0.37kW (0.5HP) 400V 3 Phase motor in VxF or Sensorless Vector control to 1.9A. Simple to set-up with 400V three phase input for a standard AC Induction motor or permanent magnet synchronous motor.
Solar Pump Software: Option included for maximum Pump output from the variable Voltage available from PV panels, or main electricity supply.
Dimensions: Size R1 70mm Wide x 161mm Deep x 169mm high (239mm high including fastenings and clamp plate).
Enclosure Rating: IP20.
Weight: 1.2kg.
Overload: 150% x 60 seconds every 10 minutes, 175% x 2 seconds at start.
Speed Control Range: 0-600Hz.
Braking: Full load for 90 seconds every 120 seconds to 175 Ohm minimum, 800 Ohm Maximum external resistor (not supplied) - see the Resistor options linked below or use the 'Which Resistor' button on this page.
Keypad: See optional products linked below.
Features: 2 x Analogue Inputs, 5 x Digital Inputs, 1 x Analogue Output, 1 x Digital Output, 1 x Relay Contact set.
DC Bus terminals with charge limit in circuit for DC supply from PV panels, or for common bus energy saving applications.
'Safe Torque Off' (STO) function to SIL 3.
Programmable from a PC via 'DriveWindow' or using the ABB FlashDrop tool.
AC Input Voltage: 380-480V Three Phase at 50/60Hz ±5%.
AC Input Current: 3.6A, or 1.8A when supplied via a minimum 6.4mH AC Input choke (see the products linked below) to reduce the metered kVA from 2.5kVA per drive, to 1.5kVA.
DC Input Voltage: 250 to 800 V DC.
DC Input Current: 1.4A Maximum.
Maximum Power Point Tracking (MPPT): 460V to 800V DC.
DC Minimum Voltage: 250Vdc for operation to be started (100% AC current is only available when Voltage is equal or higher than MPPT voltage).
DC Maximum Voltage: 840Vdc (PV Panel open circuit Voltage must not be exceeded this level under any conditions).
EMC Filters: IEC/EN 61800-3 2nd Environment C3 (Industrial)
Mounting: Cubicle mount (or Wall mount with the optional Cover and Gland Box) in a clean environment onto 35mm DIN rail, or Rear mount via 4 x 5mm diameter holes on 50mm x 191mm centres, or Side mount via 3 x 5mm diameter holes on 41 x 191mm centres.
Ambient: Rated at 40°C.
Ventilation space above and below: 75mm.
Ventilation space at sides: 0mm (drives can be mounted side by side)
Heat Loss at max output: 22W.
Part number: ACS355-03E-01A9-4+N827 (3AUA0000157187+N827).
Download the ABB ACS355 Manual from the link below:-