ABB ACH480 series AC Inverter for 18.5kW to 36A when fan/pump rated. Operates in standard VxF or Sensorless Vector Control and converts 400V 3ph input to variable frequency 400V 3ph output to control the speed of a standard AC induction motor, permanent magnet synchronous motor or synchronous reluctance motor.
Output Current: 36A
Overload: 110% for 60 seconds every 10 minutes (Fan/Pump rated)
Peak: 57.6A for 2 seconds every 10 minutes
Size R4: 262mm (W) x 205mm (H) x 213mm (D), 240mm (H) with Cable clamp.
IP Rating: IP20 (For increased IP rating see wall mounting kit below - UL1)
Weight: 5.6kg.
Speed Control Range: 0-599Hz
Dynamic Braking (DBr): 15kW continuous for minimum 6 Ohms, maximum 24 Ohms external resistor (not supplied – see linked products below).
Removable Keypad (ACH-AP-H) with USB mini-B socket for PC connection included.
I/O module included: 2 Analogue Inputs, 6 Digital Inputs, 2 Analogue Outputs, 3 Relay Contact Sets, terminals for Modbus RTU or BACnet MS/IP (EIA-485) communications.
Terminals for dual channel SIL3/PL e safe torque off (STO) included.
DC bus terminals included.
Input Current: 52.3A. (Reduces to 38A if additional Input Choke is fitted – see linked items below)
Input Voltage: 380-480 Vac, +10%/-15%, 48 to 63 Hz
No Internal DC Choke, external Input Choke available.
EMC compliance: EN 61800-3: 2004 + A1: 2012 Category C2 (Industrial or restricted Domestic) for motor cables up to 10m
Cubicle mount.
Rated Ambient: 50°C
Ventilation space above: 75mm, below: 75mm, at sides: 0mm.
Heat Loss at max output: 497W.
Mounting via 35mm DIN rail or 4 x 5.5mm diameter slotted holes at rear
Manufacturer part number is ACH480-04-039A-4