Parker SSD 890 Series AC Frequency Inverter for 1.1kW (1.5HP) 230V 3 Ph motor to 5.5A. Operates in full closed-loop Flux Vector Control with Resolver Feedback (and Repeater Output) .
Part Number 890SD-231550B0-B00-1A600
[890SD-] : AC890 Standalone Drive Module
[23] : 230VAC 3-phase input
[1550B] : 1.10kW / 5.50A Constant Torque Rating (4.00A Servo Mode) - Frame 'B'
[0-] : No Auxiliary Supply Option
[B] : Brake Switch Fitted
[00-] : No Special Option
[1] : Advanced Performance
[A] : English (50Hz) Destination
[6] : Resolver Feedback with Repeater Output
[0] : No Option Fitted (Technology Slot ''A'')
[0] : No Option Fitted (Technology Slot ''B'')
Size B - 72.4mm Wide x 258.5mm Deep x 433.6mm High. IP20
Weight: 5kg.
Overload - 150% x 60 seconds
Speed Control Range: 0-1000Hz (VxF), 0-350Hz (Closed-loop Vector), 0-120Hz (Sensorless Vector).
Braking - To 36 Ohm minimum external resistor (not supplied) - See the Resistor options linked below or use the 'Which Resistor' button on this page.
Safe Torque Off to SIL3 or PLe level as per EN ISO13849 and EN61800-5-2.
4 Analogue Inputs, 7 Digital Inputs, 2 Analogue Outputs, 2 Digital Inputs/Outputs, 1 Relay Contact Set, USB port for Programming.
Input Current - 7.7A (in Vector mode).
Input Voltage - 230Vac, 3phase ±10% at 50/60Hz
EMC Filters to EN61800-3 to the 2nd Environment (Industrial). See linked products below for external 1st Environment (Domestic) EMC Filter.
Wall mount in clean environment or cubicle mount.
Rated 40°C Ambient.
Ventilation space in front - [Not Specified], Ventilation space above and below - 150mm, Ventilation space at sides - 0mm (drives can be mounted side by side).
Mounting via 2 x holes at rear (1 top, 1 bottom) on 413.6mm centres.
Mounting onto 35mm DIN rail using included fitting kit.
Full part number is - 890SD-231550B0-B00-1A600.