LS G100 AC Frequency Inverter for 15kW (20HP) 230V 3 Ph motor to 60A at High Overload or 18.5kW (25HP) to 70A when Fan/Pump rated. Operates in VxF or Sensorless Vector Control and converts fixed frequency three phase 230V to variable frequency three phase 230V to control the speed of a standard AC Induction motor
Rating: 15kW, 60A with 150% overload for 60 seconds (High Overload)
Rating: 18.5kW, 70A with 120% overload for 60 seconds (Fan/Pump - Parameter change is required during commissioning to achieve Fan/Pump rating)
IP20 Cubicle Mount
Frame Size F: ***mm Wide x ***mm Deep x ***mm high
Speed Control Range: 0-400Hz (V/F) or 0-120Hz (Sensorless Vector)
Braking (DBr): 8 Ohm minimum external resistor (not supplied). See Resistor option linked below
Fixed Keypad with built in Potentiometer
1 x Analogue Input, 5 Digital Inputs, 1 x Analogue Output, 2 x Relay Outputs (1 Set, 1 N/C)
RS 485 Communications via RJ45 or twin wire terminal connection. Supports Modbus RTU and LS INV485 protocols
Programmable from a PC using PC Tool ‘DriveView9’
STO: Not Included
Input Current: 68.4A (High Overload), 79.8A (Fan/Pump)
Input Voltage: Three phase 200-240 Vac +10%, -15% at 50-60Hz ±5%
Single phase operation available at a reduced output approx 45% of rating.
EMC Filters: None
Rated at 40C Ambient
Losses: 380W
Ventilation space above and below: 100mm
Ventilation space at sides: 50mm; 3mm between multiple G100 Units
Ventilation space at front: 50mm
Mounting: Panel mounted with 4 x 5mm fixings on 193.8mm x 331mm Centres
Full Part Number:LV0150G100-2EONN
Previous Generation: IG5A, SV150iG5A-2
Download the LS G100 Manual from the link below:-