SSD 690+ AC Frequency Inverter without EMC Filter 3.0kW (4HP) and 4.0kW (5.5HP) to 16.5A for 230V 3 Ph motors in VxF, Sensorless Flux Vector or Full Closed Loop Flux Vector control (when the optional encoder board is fitted). Simple set-up and ready to run in VxF from its default settings.
Overload - 150% x 60 seconds.
Speed Control Range - 0/120Hz (default), 0/240Hz or 0/480Hz (set higher switching frequency and de-rate the drives for the higher ranges).
Braking - 100% duty into minimum 33 Ohm external resistor. See the Resistor options linked below or use the 'Which Resistor' button on this page.
4 x Analogue Inputs, 8 Digital Inputs, 3 Analogue outputs, 3 Digital outputs (relay contacts).
Input Current - 20A.
Input Voltage - 220/240V three phase +-10% at 50/60Hz (or de-rate by 10% for use at 208V).
Input fuse - 20A to suit input bridge at 425A²s
Cubicle mount.
Rated at 40C Ambient.
Ventilation space above and below - 80mm.
Ventilation space at sides - 15mm.
Heat Loss at max output - 200W.
Size B - 177mm Wide x 181mm Deep x 233mm High.
Mounting - M4 screw fixings on 129.5mm x 223mm centres.
Weight is 4.3kg.
Full part number is - 690-232165B0-B00P00-A400 Was 690PB-0040-230-3-0-0011-UK-0-0-0-0-0 - Exactly the same as SSD Drives and Eurotherm Drives - 690PB-0040-230-3-0-0011-UK-0-0-0-0-0. Can be specified as 690PB-0040-400-3-0-0011-PO-0-0-0-0-0 if required.