TEC Electric - 5.5kW 3ph 2 Pole Force Cooled High Efficiency Flange Mounting (B5) 132S Frame AC Motor for 400V 3 phase supply. Inverter Rated for use with a Variable Frequency Inverter Drive or a fixed frequency mains supply at 50Hz.
Fixed mains supply output: 5.5kW (7.5HP) x 2900RPM at 400V x 50Hz 3ph.
Inverter Supply Output: 14:1 Speed Control range from 290RPM to 4060RPM for 5Hz to 70Hz control, with suitable de-rating at the lower speeds.
Full Load Current - 10.2A at 400V.
Power Factor is 0.89 when mains connected at 50Hz.
Efficiency is 87.2%
Forced Ventilation Fan: 3 Phase 230/400V/50Hz (0.195A 50W) Note: Single Phase 230/50HZ option avaiable on request
252mm Wide x 547mm Long x 318mm high overall in its IP55 enclosure, including fan.
Flange mount on 15mm holes at 265mm PCD with 230mm diameter spigot in the 300mm diameter flange.
Shaft is 38mm dia x 80mm with 10mm wide key.
Weight is 47.3kg.
Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Part number is - 5.5TECAB5-IE2-FORCEVENT-132A400/230/3/50
For Variable Speed use:-
Part Time Output when Inverter powered is...
12.94Nm - 5.5kW ( 7.37HP) x 4060 RPM at 70 Hz
18.11Nm - 5.5kW ( 7.37HP) x 2900 RPM at 50 Hz
18.11Nm -2.75kW ( 3.69HP) x 1450 RPM at 25 Hz
18.11Nm - 0.55kW ( 0.74HP) x 290 RPM at 5 Hz
Continuous Output when Inverter powered is...
12.94Nm - 5.5kW ( 7.37HP) x 4060 RPM at 70 Hz
18.11Nm - 5.5kW ( 7.37HP) x 2900 RPM at 50 Hz
15.4Nm - 2.34kW ( 3.13HP) x 1450 RPM at 25 Hz
9.06Nm - 0.275kW ( 0.37HP) x 290 RPM at 5 Hz
Download the full Manual and Dimensions from the links below:-
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.