Vascat - 0/40.5/40.5kW x 0/604/1750RPM – Square Frame AC Vector Motor, foot mounting (B3) for 400V 3 phase supply.
160 Frame, Force Ventilated (IC06) to IP23.
Includes force cooling fan, intake filter, Ball bearing at DE, 2 x Bearing Grounding Brushes and 2048ppr x 15V HTL Encoder.
Use with Closed Loop AC Vector Drives having the encoder board option fitted for full closed loop vector control.
Continuous Output: 40.5kW.
Overload: 150% to S6 (40%), subject to reduced maximum speed.
Base Speed: 604RPM.
Maximum Speed at Full Output: 1750RPM.
Torque to Base Speed: 640Nm.
Torque at Maximum Speed: 221Nm.
Full Load Current: 79A.
Voltage: 400V 3 Phase.
Supply Frequency: 21/61Hz at Base/Maximum Speed.
Magnetising Current: 35A.
Overall Dimensions: 354mm Wide x 971mm Long x 699mm high overall.
Mounting: Foot mount on 14mm holes at 254mm wide x 560mm centres.
Weight: 355kg.
Rotor Inertia: 0.432kgm2.
Shaft: 60mm diameter x 140mm from shoulder with 18mm wide keyway.
Drive End Bearing: Ball Bearing for a direct connected load.
Bearing Protection: Bearing Current Bypass Brushes fitted to NDE and DE as Standard.
Ambient Temperature: 40C at up to 1000m above sea level.
Cooling: Force Ventilation Fan with Intake Filter fitted at 0.75kW for 400V 3ph 50Hz supply at 1.8A.
Part number: MAC-QI-160X-B41-B3-SBB-2186. (MACQI160X-B41-B3-SBB-2048ppr)
Download the MAC-QI-160X Dimension drawing and output curves from the link below...