Parker SSD 890 Series AC Frequency Inverter for 1.1kW (1.5HP) 400V 3 Ph motor to 3.5A. Operates in VxF, Suitable for a Standard AC Induction Motor in VxF, Sensorless Vector Control or Full Closed Loop Vector Control with an optional Speed Feedback Card. Also suitable to control a PM Brushless AC Servo Motor when fitted with an optional Feedback Card. (See Feedback Options below)
The 890CD is a modular Inverter designed for energy-saving or space-saving Common DC Bus applications. It requires an 890 Common DC Bus supply unit to function correctly - see linked products below.
Advanced Performance - includes Basic LINK VM function blocks: math functions, Boolean logic, timers, counters, One shots, threshold comparators, latches, plus: motion control firmware with added position loop, motion control function blocks, move incremental, move absolute, move home, line drive master ramp and section control, winder blocks (SPW, CPW), full function PID, state machine, and others.
Size B - 72.4mm Wide x 258.5mm Deep x 433.6mm High. IP20
Weight: 5.0kg.
Overload - 150% x 60 seconds
Speed Control Range: 0-1000Hz (VxF), 0-350Hz (Closed-loop Vector), 0-120Hz (Sensorless Vector).
Braking - not applicable (provided by Common DC Bus supply unit).
4 Analogue Inputs, 7 Digital Inputs, 2 Analogue Outputs, 2 Digital Inputs/Outputs, 1 Relay Contact Set, USB port for Programming.
Safe Torque off to SIL3 or PLe level per EN ISO13849 and EN61800-5-2
Input Current - 5.0A (Vector Mode)
Input Voltage - 560V DC / 650-705V DC supplied by 890 Common DC Bus Supply unit.
EMC Filters - to EN61800-3 2nd Environment (Industrial).
Wall mount in clean environment or cubicle mount.
Rated 45°C Ambient.
Ventilation space in front - [Not Specified]
Ventilation space above and below - 150mm.
Ventilation space at sides - 0mm (drives can be mounted side by side).
Mounting via 2 x holes at rear (1 top, 1 bottom) on 413.6mm centres.
Mounting onto 35mm DIN rail using included fitting kit.
Option Modules were originally supplied fitted to the 890CD, Modules are now supplied as additional items (Please see linked items below).
Additional option cards are required to achieve the variants given below:
Part Number Variation in block 4 (Legacy Part Variations in blocks 10): 1(E1), 3(EQ), 5(RE), 6(RR), 7(M1), L(LS) eg 890SD-531200B0-B00-1A300 (890SD/5/0002B/B/00/A/UK/00/00/EQ/00/00) was supplied with an Encoder Feedback Option card 8902-EQ-00 fitted.
Part Number Variation in block 4 (Legacy Part Variations in block 11): N(CB), C(CN), D(DN), H(IP), T(IM), P(PB), 7(M1), S(RS), K(CT), E(EP) eg 890SD-531200B0-B00-1A0P0 (890SD/5/0002B/B/00/A/UK/00/00/00/PB/00) was supplied with Profibus Communications Card 8903-PB-00 fitted
Full part number is - 890CD-531350B0-000-1A000. Legacy part number is 890CD/5/0003B/N/00/A/UK/00/00/00/00/00
Model number is - 890CD/5/0003B.
Download the Parker 890 Installation Manual and 890 Common DC Bus Quick Start Guide from the links below:-