Teco A510 Series AC Inverter for 11kW (15HP) 400V 3 Ph motor to 24A at high overload, or 15kW (20HP) to 31A when Fan/Pump rated. Operates in VxF, Sensorless Vector or Full Closed-loop Flux Vector (when the optional Encoder Feedback card is fitted). Converts fixed frequency three phase 400V input to variable frequency three phase 400V to control the speed of a standard AC induction motor or permanent magnet synchronous motor.
Size 3: 210mm Wide x 215mm Deep x 385mm High.
Weight: 7.72kg.
Overload: 150% x 60 seconds, 200% x 2 seconds (High Overload)
Overload: 120% x 60 seconds (Fan/Pump rated)
Speed Control Range: 0-1200Hz (depending on control mode)
Braking: Minimum 50 Ohm minimum external resistor (not supplied) - See the Resistor options linked below or use the 'Which Resistor' button on this page.
2 Analogue Inputs, 8 Digital Inputs, 1 Pulse Input, 2 Analogue Outputs, 2 Digital Outputs, 2 Relay Contact sets, 1 Pulse Output, 1 Safety Switch, RJ45 port for Modbus RS485 Communications.
Input Current: 25A (high overload), 32.3A (fan/pump rated)
Input Voltage: 380-480V Three Phase +10% -15% at 50-60Hz ±5%
EMC Filters: IEC EN61800-3 (Industrial).
Wall mount in clean environment or cubicle mount.
Rated 40°C Ambient.
Ventilation space in front: [not specified], Ventilation space above and below: 150mm, Ventilation space at sides: 200mm.
Heat Loss at max output: [not specified]
Mounting via 4 x holes at rear for M6 screws on 192mm x 286mm centres.
Manufacturer part number is A510-4015-H3F.
Download the Teco A510 Manual and Quick Start Guide from the links below:-