SSD AC30P AC Frequency Inverter for 30kW (40HP) 400V 3 Ph motor to 60A at high overload or 37kW (50HP) to 73A when Fan/Pump rated, operates in VxF, Sensorless Flux Vector or Full Closed Loop Flux Vector control (when the optional encoder board is fitted). Simple set-up and ready to run in VxF from its default settings.
Size G- 220mm Wide x 287mm Deep x 480mm High overall. IP20
Weight: 22.3kg
Overload - 150% x 60 seconds and 180% for 3.0seconds.
Speed Control Range - 0/500Hz (default), 0/1000Hz or 0/1500Hz
Switching Frequency 4 to 16kHz.(Derating may apply)
Braking (DBr) - Maximum of 20 seconds at maximum current @ a duty 30% into minimum 13 Ohm external resistor - See the Resistor options linked below or use the 'Which Resistor' button on this page
Brake Switch Peak Current 59A (@30% Duty) Continuous current 39A@30kW
Graphical Keypad (HMI)
2 x Analogue Inputs, 3 Digital Inputs,4 Programmable Digital I/O, 2 Analogue outputs, 2 Digital outputs (relay contacts). 2 EtherNet Ports.
EtherNetIP or ProfiNet available with firmware upgrade.
Input Current –54.7A at high overload or 66.2A when Fan/Pump rating set.
Input Voltage - 380/480V three phase +-10% at 50/60Hz.
Input fuse - 100A when Fan/Pump rating set
Filters: EMC Compliance: IEC EN 61800-3 Category C3 (Industrial). Can be disconnected if required.
Standard 3C3 coated PCBs
Safety Features: STO & Safe Stop (SS1)
Wall mount in clean environment or cubicle mount.
Rated at 40C Ambient
Ventilation space Front - 10mm
Ventilation space above and below - 75mm.
Ventilation space at sides - 0mm.
Heat Loss at max output - Not Specified (estimated efficiency 98%)
Mounting –M5 screw fixings on 190mm x 465mm centres.
Manufacturer Part Number is 31P-4G0073-BE-2S-0000.
The AC30 Technical Manuals can be downloaded from the link below:-