TEC Electric - 0.55kW 3ph 4 Pole Flange Mounting 80 Frame AC Motor for 230V or 400V 3 phase supply. Inverter Rated for use with a Variable Frequency Inverter Drive having 1ph or 3ph input and 3ph output, or a fixed frequency mains supply at 50Hz.
**Available from stock only**
Fixed Main Supply Output: 0.55kW (0.75HP) x 1370RPM at 230V or 400V x 50Hz 3ph.
Inverter Drive Supply Output: 14:1 Speed Control range from 137RPM to 1918RPM at 5Hz to 70Hz, with suitable de-rating at the lower speeds (70Hz is the maximum continuous for maximum output, as advised by the Manufacturer).
Full Load Current: 2.75A at 230V, or 1.59A at 400V.
Efficiency: 72%. A more efficient motor is available, please see linked products below
Power Factor: 0.78 when mains connected at 50Hz.
Set terminal box links 'three a-breast' for 230V 'Delta' connection.
Set terminal box links ‘two at one side’ for 400V 'Star' connection.
Dimensions: 158mm/160mm Wide x 290mm Long x 217mm high overall.
Enclosure Rating: IP55.
Mounting: Flange mount on 11mm holes at 165mm pcd with 130mm dia spigot in the 200mm diameter flange.
Shaft: 19mm dia x 40mm with 6mm wide key.
Weight: 9kg.
Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for external over-temperature protection circuit is included.
Manufacturer Part Number is 0.5543TECAB5. Previous Part Number was - 80M4A-TECA B5 (80 M4A TEC-A)
For Variable Speed Use…
Part Time Output when Inverter powered is...
1.82Nm - 0.55kW (0.75HP) x 2740RPM at 100Hz
3.84Nm - 0.55kW (0.75HP) x 1370RPM at 50Hz
3.84Nm - 0.275kW (0.375HP) x 685RPM at 25Hz
3.84Nm - 0.055kW (0.075HP) x 137RPM at 5Hz
Continuous Output when Inverter powered is...
2.74Nm - 0.55kW (0.75HP) x 1918RPM at 70Hz
3.84Nm - 0.55kW (0.75HP) x 1370RPM at 50Hz
3.26Nm - 0.23kW (0.31HP) x 685RPM at 25Hz
1.82Nm - 0.0275W (0.037HP) x 137RPM at 5Hz
Extended Warranty Available: When a TEC AC Motor is used with a TECDrive AC Inverter (see linked products below) the warranty period is 2 years (from dispatch). Standard warranty is 1 year.
For the extended warranty to be valid the TEC AC Inverter and TEC Motor must be on the same order and used together when on site.