TEC Electric - 5.5kW 3ph 6 Pole High Efficiency Foot Mounting (B3) 132M Frame AC Motor for 400V 3 phase supply. Inverter Rated for use with a Variable Frequency Inverter Drive or a fixed frequency mains supply at 50Hz.
Fitted with +150°c (SKF GJN) High temp bearing at DE
Fixed mains supply output: 5.5kW (7.5HP) x 960RPM at 400V x 50Hz 3ph.
Inverter Supply Output: 20:1 Speed Control range from 96RPM to 1920RPM for 5Hz to 70Hz control, with suitable de-rating at the lower speeds.
Full Load Current - 12A at 400V.
Power Factor is 0.77 when mains connected at 50Hz.
Efficiency is 86%
252mm Wide x 475mm Long x 318mm high overall in its IP55 enclosure.
Foot mount on 12mm holes at 216mm wide x 178mm centres 89mm back from the shaft shoulder.
Shaft is 38mm dia x 80mm with 10mm wide key.
Weight is 53.5kg.
Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Part number is - TECA2-132M2-6-HT 150C DE
For Variable Speed use:-
Part Time Output when Inverter powered is...
27.36Nm - 5.5kW ( 7.37HP) x 1920 RPM at 100 Hz
54.71Nm -5.5kW ( 7.5HP) x 960 RPM at 50 Hz
54.71Nm -2.75kW ( 3.69HP) x 480 RPM at 25 Hz
54.71Nm - 0.55kW (0.74HP) x 96 RPM at 5 Hz
Continuous Output when Inverter powered is...
39.1Nm - 5.5kW ( 7.37HP) x 1344 RPM at 70 Hz
54.71Nm - 5.5kW ( 7.5HP) x 960 RPM at 50 Hz
46.51Nm - 2.34kW ( 3.13HP) x 480 RPM at 25 Hz
27.36Nm - 0.28kW (0.37HP) x 96 RPM at 5 Hz
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.