TEC IE2 18.5kW Cast Iron Three Phase Motor 400V 6 Pole 200L B3 Foot Mount with Roller Bearing

18.563TECCB3-IE2+Roller Brg

Order Code: 27053
Obsolete Product
This item is now obsolete. Alternatives may be available - see linked products below.

Brand: TEC Electric Motors, Range: TECC IE2 Three Phase Cast Iron

TEC Electric - 18.5kW 3ph 6 Pole Cast Iron High Efficiency Foot Mounting (B3) 200L Frame AC Motor for 400V 3 phase supply with roller bearing.  Inverter Rated for use with a Variable Frequency Inverter Drive  or a fixed frequency mains supply at 50Hz.

Fixed mains supply output: 18.5kW (24.8HP) x 975RPM at 400V x 50Hz 3ph.
Inverter Supply Output: 14:1 Speed Control range from 97.5RPM to 1365RPM for 5Hz to 70Hz control, with suitable de-rating at the lower speeds.

Full Load Current - 35.6A at 400V.
Power Factor is 0.83 when mains connected at 50Hz.
Efficiency is 90.4%

390mm Wide x 745mm Long x 460mm high overall in its IP55 enclosure.
Foot mount on 19mm holes at 318mm wide x 305mm centres 133mm back from the shaft shoulder.
Shaft is 55mm dia x 110mm with 16mm wide key.
Drive End Bearing: SKF NJ Roller Bearing for belt side load.
Weight is 232kg.

Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Part number is - 18.563TECCB3-IE2+Roller Brg

For Variable Speed use:-
Part Time Output when Inverter powered is...
90.6Nm - 18.5kW ( 24.8HP) x 1950 RPM at 100 Hz
181.21Nm -18.5kW ( 25HP) x 975 RPM at 50 Hz
181.21Nm -9.25kW ( 12.4HP) x 488 RPM at 25 Hz
181.21Nm - 1.85kW (2.48HP) x 98 RPM at 5 Hz
Continuous Output when Inverter powered is...
129.4Nm -18.5kW ( 24.8HP) x 1365 RPM at 70 Hz
181.21Nm -18.5kW ( 25HP) x 975 RPM at 50 Hz
154.02Nm - 7.86kW ( 10.54HP) x 488 RPM at 25 Hz
90.6Nm - 0.93kW (1.24HP) x 98 RPM at 5 Hz

Extended Warranty Available: When a TEC AC Motor is used with a TECDrive AC Inverter (see linked products below) the warranty period is 2 years (from dispatch). Standard warranty is 1 year.
For the extended warranty to be valid the TEC AC Inverter and TEC Motor must be on the same order and used together when on site.

From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.

You may also be interested in...

Photo of TEC Force Ventilation Fan for 200 Frame Motor, 230V/400V 3ph

TEC Force Ventilation Fan for 200 Frame Motor, 230V/400V 3ph

200-FORCEVENT-400V

Order code: 33066

Delivery 3-5 days

£430.00
£408.50
£387.00
1+
5+
10+