TEC Electric - 18.5kW 3ph 6 Pole High Efficiency Flange Mounting (B5) 200L Frame AC Motor for 400V 3 phase supply. Inverter Rated for use with a Variable Frequency Inverter Drive or a fixed frequency mains supply at 50Hz.
Fixed mains supply output: 18.5kW (24.8HP) x 975RPM at 400V x 50Hz 3ph.
Inverter Supply Output: 20:1 Speed Control range from 97.5RPM to 1950RPM for 5Hz to 70Hz control, with suitable de-rating at the lower speeds.
Full Load Current - 35.6A at 400V.
Power Factor is 0.83 when mains connected at 50Hz.
Efficiency is 90.4%
390mm Wide x 745mm Long x 460mm high overall in its IP55 enclosure.
Flange mount on 19mm holes at 350mm PCD with 300mm diameter spigot in the 400mm diameter flange.
Shaft is 55mm dia x 110mm with 16mm wide key.
Weight is 132kg.
Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Part number is - TECA2-200L1-6-B5
For Variable Speed use:-
Part Time Output when Inverter powered is...
90.6Nm - 18.5kW ( 24.8HP) x 1950 RPM at 100 Hz
181.21Nm -18.5kW ( 25HP) x 975 RPM at 50 Hz
181.21Nm -9.25kW ( 12.4HP) x 488 RPM at 25 Hz
181.21Nm - 1.85kW (2.48HP) x 98 RPM at 5 Hz
Continuous Output when Inverter powered is...
129.4Nm -18.5kW ( 24.8HP) x 1365 RPM at 70 Hz
181.21Nm - 18.5kW ( 25HP) x 975 RPM at 50 Hz
154.02Nm - 7.86kW ( 10.54HP) x 488 RPM at 25 Hz
90.6Nm - 0.93kW (1.24HP) x 98 RPM at 5 Hz
Extended Warranty Available: When a TEC AC Motor is used with a TECDrive AC Inverter (see linked products below) the warranty period is 2 years (from dispatch). Standard warranty is 1 year.
For the extended warranty to be valid the TEC AC Inverter and TEC Motor must be on the same order and used together when on site.
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.