TEC Electric 0.75kW 3ph 2 Pole 71 Frame Foot and Face mounting AC Motor for 230V or 400V 3 phase supply. Inverter Rated for use with a Variable Frequency Inverter Drive having 1ph or 3ph input and 3ph output, or a fixed frequency mains supply at 50Hz.
Fixed Main Supply output: 0.75kW (1.0HP) x 2730RPM at 230V or 400V x 50Hz 3ph.
Inverter Drive Supply Output: 14:1 Speed Control range from 273RPM to 3822RPM at 5Hz to 70Hz, with suitable de-rating at the lower speeds.
Full Load Current: 3.24A at 230V, or 1.87A at 400V.
Power Factor: 0.83 when mains connected at 50Hz.
Efficiency: 72% at full load.
Set terminal box links 'three a-breast' for 230V 'Delta' connection.
Set terminal box links ‘two at one side’ for 400V 'Star' connection.
Dimensions: 132mm Wide x 255mm Long x 188mm high overall.
Enclosure Rating: IP55.
Face mount on 4 x M6 holes equispaced on 85mm PCD with 70mm spigot in the 105mm diameter flange.
Foot mount on 7mm holes at 112mm wide x 90mm centres 45mm back from shaft shoulder.
Shaft: 14mm dia x 30mm with 5mm wide key.
Terminal box: For 2 x M20 Glands (one fitted) and terminals for M4 rings.
Weight: 6kg.
Ambient: Rated at 40C.
Ventilation space required at rear cooling air intake.
Thermistors Included for external over-temperature protection device.
Part number: 0.7523TECAB34-71.
For Variable Speed use...
Part Time Output when Inverter powered is:
1.87Nm - 0.75kW (1HP) x 3822RPM at 70Hz
2.62Nm - 0.75kW (1HP) x 2730RPM at 50Hz
2.62Nm - 0.375kW (0.5HP) x 1365RPM at 25Hz
2.62Nm - 0.075kW (0.1HP) x 273RPM at 5Hz
Continuous Output when Inverter powered is:
1.87Nm - 0.75kW (1HP) x 3822RPM at 70Hz
2.62Nm - 0.75kW (0.75HP) x 2730RPM at 50Hz
2.22Nm - 0.32kW (0.43HP) x 1365RPM at 25Hz
1.31Nm - 0.037kW (0.05HP) x 273RPM at 5Hz
Download the Dimensions and Technical Catalogue from the links below...
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.