TEC 160kW 3ph 4 Pole High Efficiency Foot Mounting AC Motor in 315 frame with Insulated Bearing for 400V 3 phase supply. Suitable for use with a Variable Frequency Inverter Drive.
Totally enclosed to IP55, including a shaft mounted cooling fan.
Inverter Rated for use with a suitable AC Frequency Inverter Drive over a wide speed control range with suitable de-rating at the lower speeds.
Fixed Supply Output: 160kW (215HP).
Speed: 1480RPM.
Voltage: 400V x 50Hz 3ph.
Full Load Current: 267.4A at 400V.
Efficiency: 94.9% at full load.
Efficiency Class: IE2.
Power Factor: 0.91 when mains connected at 50Hz.
Set terminal box links 'three a-breast' for 400V 'Delta' connection.
Set terminal box links ‘two at one side’ for 690V 'Star' connection.
Enclosure Rating: IP55.
Dimensions: 630mm Wide x 1385mm Long x 845mm high overall.
Foot mount on 28mm holes at 508mm wide x 457mm/508mm centres 216mm back from shaft shoulder.
Drive End Bearing: Ball Bearing for a direct connected load.
Weight: 1070kg.
Ambient Temperature: Rated at 40C.
Ventilation space required at rear cooling air intake.
Thermistors included for use with an external over-temperature protection device.
Part Number: 160.043TECCB3-IE2-INS.
For Variable Speed use:-
Part Time Output when Inverter powered:
860Nm, 160kW (215HP) x 1776RPM at 60Hz.
1032Nm, 160kW (215HP) x 1480RPM at 50Hz.
1032Nm, 80kW (107HP) x 740RPM at 25Hz.
1032Nm, 16kW (21HP) x 148RPM at 5Hz.
Continuous Output when Inverter powered:
860Nm, 160kW (215HP) x 1776RPM at 60Hz.
1032Nm, 160kW (215HP) x 1480RPM at 50Hz.
877Nm, 68kW (91HP) x 742RPM at 25Hz.
516Nm, 8kW (10.7HP) x 148RPM at 5Hz.
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.
Download the full Technical Catalogue from the link below...
From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.