TEC Electric – IE2 4kW (5.5HP) 6 Pole AC Motor 400V B3 Foot Mount - 132M Frame with 1024ppr Encoder

TECA2-132M1-6-B3-ENC-1024

Order Code: 31372
Obsolete Product
This item is now obsolete. Alternatives may be available - see linked products below.

Brand: TEC Electric Motors, Range: TECA Three Phase Aluminium

TEC Electric - 4kW 3ph 6 Pole High Efficiency Foot Mounting (B3) 132M Frame AC Motor for 400V 3 phase supply.  Inverter Rated for use with a Variable Frequency Inverter Drive  or a fixed frequency mains supply at 50Hz.

Fixed mains supply output: 4kW (5.5HP) x 960RPM at 400V x 50Hz 3ph.
Inverter Supply Output: 20:1 Speed Control range from 96RPM to 1920RPM for 5Hz to 70Hz control, with suitable de-rating at the lower speeds.

Full Load Current - 8.86A at 400V.
Power Factor is 0.77 when mains connected at 50Hz.
Efficiency is 84.6%

Fitted with 1024ppr encoder and extended Cowl (No Force Ventilation). Encoder Type: IH581 1024ppr (5-30V)

252mm Wide x XXXmm Long x 318mm high overall in its IP55 enclosure.

Foot mount on 12mm holes at 216mm wide x 178mm centres 89mm back from the shaft shoulder.
Shaft is 38mm dia x 80mm with 10mm wide key.
Weight is 45kg.

Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Part number is - TECA2-132M1-6-B3

For Variable Speed use:-
Part Time Output when Inverter powered is...
19.9Nm - 4kW ( 5.36HP) x 1920 RPM at 100 Hz
39.79Nm -4kW ( 5.5HP) x 960 RPM at 50 Hz
39.79Nm -2kW ( 2.68HP) x 480 RPM at 25 Hz
39.79Nm - 0.4kW (0.54HP) x 96 RPM at 5 Hz
Continuous Output when Inverter powered is...
28.4Nm -4kW ( 5.36HP) x 1344 RPM at 70 Hz
39.79Nm -4kW ( 5.5HP) x 960 RPM at 50 Hz
33.82Nm - 1.7kW ( 2.28HP) x 480 RPM at 25 Hz
19.9Nm - 0.2kW (0.27HP) x 96 RPM at 5 Hz

Download the full Manual and Dimensions from the links below:-

From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.