Universal GD200A Series AC Inverter for 5.5kW (7.5HP) 400V 3-phase motor to 14A at high overload or 7.5kW (10HP) to 18.5A when fan and pump rated. Operates in standard VxF or Sensorless Vector Control and Converts fixed frequency three phase 400V input to variable frequency three phase 400V to control the speed of a standard AC Induction motor.
**Available from stock only - see replacement product below**
Output Current: 14A
High Overload: 150% x 60 seconds; 200% x 1 second.
Output Current 18.5A
Fan and Pump Overload: 120% x 60 seconds
Dimensions: Size 2; 146mm Wide x 181mm Deep x 256mm High.
Enclosure Rating: IP20.
Weight: 3kg.
Speed Control Range: 0-400Hz
Braking (DBr): Internal Braking Switch fitted.
Braking Resistor (not supplied): 60 Ohm minimum – Fit resistor only if braking is required; see linked products below.
Fixed Keypad with 5 x 7 segment LED display.
2 Analogue Inputs, 8 Digital Inputs, 2 Analogue Outputs, 1 Digital Output, 2 Relay Contact sets, 1 High Frequency Input (50kHz), 1 High Frequency Output (0-50kHz)
Twin wire connection for RS485 Communications. (Modbus ASCII & Modbus RTU protocols)
Input Current: 19.5A High Overload, 25A Fan and Pump rated.
Input Voltage: Three Phase 380-440Vac (+10% -15%) 50/60Hz (47-63Hz)
EMC Filters: IEC EN61800-3 Second Environment (Industrial – C3).
EMC Filter may be disabled. J10 should be fitted to enable the EMC Filter.
Mounting: Cubicle mount via 4 x holes at rear for 6mm screws on 131 x 244mm centres.
Ambient: Rated at 40°C; 50°C Max with de-rate.
Ventilation space in front: [not specified], Ventilation space above and below: 100mm, Ventilation space at sides: 100mm.
Heat Loss at max output: Not given
Part number: GD200A-5R5G/7R5P-4 (GD200A5R5G7R5P4)