Delta ME300 IP20 0.75kW 3ph 400VAC Inverter, DBr, STO, C3 EMC

VFD2A7ME43AFSAA

Order Code: 34628
1 in stock (2+ normally 5-7 days)
Order by 3pm for next working day delivery*

List Price: £260.61

£174.61
(excl. VAT)
£209.53
(inc. VAT )
Price break
per unit
1+
£174.61
10+
£162.88

Condition: New with Warranty
Brand: Delta, Range: VFD-ME300

Delta ME300 Basic Compact Series AC Inverter for 0.75kW (1HP)  3ph motor to 2,7A at high overload or 0.75kW (1HP) to 3,0A when Fan/Pump rated. Operates in VxF or Sensorless Vector and converts fixed frequency Three Phase  input to variable frequency Three Phase  to control a standard AC induction, permanent magnet motor, IPM (Interior permanent magnet) and SPM (surface mounted permanent magnet).

Input Current: 2,7A at High Overload, 3,0A when Fan/Pump rated.
Input Voltage: Three phase AC 380V–480V (-15 %~+10 %), 50/60 Hz.
EMC Compliance: IEC EN 61800-5-1 Category C3 @ 30m (Industrial). Disabled by default, can be enabled via screw.

Frame Size: B3 72mm Wide x 143mm Deep x 142mm High. IP20.
Mounting via 4 x M5 bolts (not supplied) at rear on 60mm x 130mm centres. (Optional DIN-Rail mounting available - see linked products below).
Weight: .9kg.

Overload:
150% for 60 seconds. High Overload. (Heavy Duty, HD), 200% of rated output current for 3 seconds.
120% for 60 seconds. Fan/Pump Rated. (Normal Duty, ND), 150% of rated output current for 3 seconds.

Speed Control Range: 0-599Hz. +/- 0.1%.
1 : 50 (V/f, SVC control for IM, heavy duty).
1 : 20 (SVC control for PM, heavy duty).
Switching (Carrier frequency): 2-15 kHz.

Braking (DBr): Built-in braking transistor for 125% Torque x 10 seconds every 100 seconds to 750 Ohm minimum external resistor (not supplied). Recommended resistor 190 Ohms 80W - see the Resistor options linked below or use the 'Which Resistor' button on this page. (Does not have to be used; available if required)

Product Features: Integrated Operator Keypad with integral potentiometer, (Option external keypad can be connected to the RS485 port (RJ45)) - see linked products below.
1 Analogue Input (0-10Vdc, 0-20mA & 4-20mA), 5 Programmable Digital Inputs (PNP/NPN), 1 Pulse Input (10kHz), 1 Analogue Output, 1 Digital Output,Modbus RS485 (RJ45)
1 Relay set of Changeover contacts (Resistive Load 3A/250VAC -5A/30VDC,  Inductive Load 1.2A/250VAC -2A/30VDC)
Common DC Bus Terminals

Safe Torque Off (STO): Functional to SIL2 (EN61800), EN 60204-1 Category 0, EN 62061 SIL CL 2, SO 13849-1:2015 Category 3 PL d.

​Environment and installation:
Pollution degree 2, Indoor use only, Cubicle mount only.
Rated at IP20
Humidity: 90%
Altitude: 0 ~ 1000m for normal operation
Heat Loss at High Overload: 48.3W total at max output

Cooling: Fan cooling.
Ambient operating temperature to 50°C (40°C when units mounted side-by-side)
Ventilation space in front [not specified], above: 50mm, below: 50mm, at sides 30mm.

Certification: CE, UL, RoHS RCM, TUV, REACH, KC.