Parker AC10 series AC Frequency Inverter for 11kW (15HP) 400V three phase motor in VxF or Sensorless Vector control to 23A. Converts fixed frequency three phase 400V input to variable frequency three phase 400V to control the speed of a standard AC Induction motor or permanent magnet synchronous motor.
Dimensions: Size 4 156mm Wide x 170mm Deep x 265mm High (excluding 15mm earth clamp).
Enclosure rating: IP20.
Weight: 4.9kg.
Overload: 150% x 60 seconds.
Speed Control Range: 0.5-590Hz.
Braking: 100% Part Time or 80% duty to minimum 50 Ohm external resistor (not supplied) - see the Linked Products below or use the 'Which Resistor' button on this page.
Features: Integrated Keypad, 2 Analogue Inputs, 6 Digital Inputs, 2 Analogue Outputs, 1 Digital Output, 1 Relay Contact set, Terminals for Modbus RS485 Communications.
RJ11 port for commissioning using free DSELite PC software (download via link below). Parameter clone port.
Note: For 22kW and below, build standards earlier than 1.02 have 5 Digital Inputs, 1 Analogue Output and RS485 terminals on the front instead of on the side of the unit.
Input Current: 24A.
Input Voltage: 380V-480V Three Phase +10% -15% at 50-60Hz.
EMC Compliance: No integrated EMC filters.
Mounting: Cubicle mount via holes at rear for M5 screws on 146mm x 255mm centres.
Ambient: Rated 40°C.
Ventilation space in front: [not specified], above and below: 150mm, at sides: 50mm.
Heat Loss: [not specified]
Part Number: 10G-44-0230-BN.
Download the Parker SSD AC10 Manual and Quick Start Guide from the links below:-