Parker AC10 series AC Frequency Inverter for 0.75kW (1HP) 400V three phase motor in VxF or Sensorless Vector control to 2A. Converts fixed frequency three phase 400V input to variable frequency three phase 400V to control the speed of a standard AC Induction motor or permanent magnet synchronous motor.
Size 2: 106mm Wide x 150mm Deep x 180mm High (excluding 15mm earth clamp). IP20.
Weight: 1.76kg.
Overload: 150% x 60 seconds
Speed Control Range: 0.5-590Hz
Braking: 100% duty to minimum 120 Ohm, maximum 600 Ohm external resistor (not supplied) - see the Linked Products below or use the 'Which Resistor' button on this page.
Integrated Keypad, 2 Analogue Inputs, 6 Digital Inputs, 2 Analogue Outputs, 1 Digital Output, 1 Relay Contact set, Terminals for Modbus RS485 Communications.
RJ11 port for commissioning using free DSELite PC software (download via link below). Parameter clone port.
Note: For 22kW and below, build standards earlier than 1.02 have 5 Digital Inputs, 1 Analogue Output and RS485 terminals on the front instead of on the side of the unit.
Input Current: 3A
Input Voltage: 380-480V Three Phase +10% -15% at 50-60Hz
EMC Compliance: IEC EN 61800-3 Category C3 (Industrial).
Cubicle mount.
Rated 40°C Ambient.
Ventilation space in front: [not specified], above and below: 150mm, at sides: 50mm.
Heat Loss at max output: [not specified]
Mounting via holes at rear for M4 screws on 94mm x 170mm centres.
Manufacturer part number is 10G-42-0020-BF.
Download the Parker SSD AC10 Manual and Quick Start Guide from the links below:-