Danfoss VLT Micro Drive FC51 Series AC Frequency Inverter for 0.37kW (0.5HP) 400V 3 Phase Motor in VxF and Sensorless Vector Control (VVC) to 1.2A.
Output Current Rating: 1.2A
Overload: 150% x 60 seconds.
Size: M1 - 70mm Wide x 155.6mm Deep x 150mm High. IP20.
Weight: 1.1kg.
Speed Control Range: 0-200 Hz (VVC+), 0-400 Hz (VxF).
Braking (DBr): Not fitted
Keypad (HMI) Not supplied, see linked items below for more details
2 x Analogue Inputs, 5 x Digital Inputs, 1 x Analogue Output, 1 x Relay Contact set.
Communications: RS485 (twin-wire); FC Protocol, Modbus RTU.
Programmable from a PC via Danfoss MCT 10 Software. (via RS485 port)
Input Current: 2.6A max
Input Voltage: 380-480V ±10% at 50-60Hz.
EMC Filters: To IEC/EN 61800-3 2nd Environment (Industrial); 1st Environment with restrictions – C2
Cubicle mount.
Ambient: Rated at 40°C
Ventilation space above and below: 100mm.
Ventilation space at sides: 0mm (drives can be mounted side by side)
Heat Loss at max output: 25.5W.
Mounting: Via 4 x 5mm diameter holes at rear on 59mm x 166.4mm centres
Full part number (without Keypad): 132F0017
Type Code: FC-051PK37T4E20H3
Download the Danfoss Micro Drive FC-51 Manual from the link below:-