ABB Drives ACS355 IP66 Sensorless Flux Vector AC Frequency Inverter for 5.5kW (7.5HP) 400V 3 Ph motor in VxF or Vector control to 12.5A. Simple to set-up for a standard AC Induction motor.
IP66 / UL Type 4X protection for the harshest and most demanding of conditions. See linked products below for compatible options and standard (IP20) equivalent.
R3 Size - 246mm Wide x 277mm Deep x 436mm high. IP66 case.
Overload - 150% x 60seconds.
Speed Control Range - 0/500Hz.
Braking at full load for 15 seconds every 120 seconds to 40 Ohm minimum, 80 Ohm Maximum external resistor (not supplied) - 56 Ohm resistor is linked below or use the 'Which Resistor' button on this page.
Features - Assistant Operator Panel (Advanced Keypad), 2 x Analogue Inputs, 5 x Digital Inputs, 1 x Analogue Output, 1 x Digital Output, 1 x Relay Contact set.
DC Bus terminals with charge limit in circuit for DC supply or common bus energy saving applications.
'Safe Torque Off' function to SIL 3.
Programmable from a PC via 'DriveWindow' or using the ABB FlashDrop tool.
Input Current - 18.8A.
Input Voltage - 380-480V three phase at 48-63Hz.
EMC Filters to EN61800-3 to the 2nd Environment (Industrial).
Rated at 40C Ambient.
Ventilation space above and below - 75mm.
Ventilation space at sides - Ensure that there is enough free space around the drive to clean it.
Heat Loss at max output - 161.2W.
Wall Mounting using 4 x screw fixings at rear. Use spacers and fastening lugs to provide clearance for cleaning.
Full part number is - ACS355-03E-12A5-4+B063 (ACS355-03E-12A5-4+B063) and is a direct replacement for the equivalent ACS350.
Download the ABB ACS355 Manual and IP66 Supplement from the links below:-