Teco E510s Series AC Inverter for 2.2kW (3HP) 230V 3 Ph motor in V/F or Sensorless Vector control to 10.5A. Converts fixed frequency single phase 230V input to variable frequency three phase 230V to control the speed of a standard AC Induction Motor or PM Synchronous Motor.
Frame: 2, 198mm Wide x 236mm Deep (Including Potentiometer) x 335mm High
Enclosure rating: IP66 with Isolator and Speed Potentiometer.
Weight: 6kg.
Output: 10.5A, 2.2kW at 400V
Overload: 150% x 60 seconds. 200% for 2 seconds
Speed Control Range: 0-599Hz
Braking (DBr): Built-in braking transistor. A 50 Ohm (minimum), 70 Ohm (100% braking torque; 10% duty cycle) external resistor is required for Dynamic Braking. Resistor is not supplied and should only be fitted if this feature is required. Resistor option given below.
LED Keypad with Potentiometer
Features: 2 Analogue Inputs, 6 Digital Inputs, 1 Analogue Output, 1 Relay Contact set, 1 NC Relay
Fieldbus: Modbus (RTU and ASCII) and BACnet communication interface included
Safety Function: STO (Safe Torque Off) Dedicated dual input up to SIL2, PLd (Linked out as default, remove links to add safety circuit)
Input Current: 24A
Input Voltage: 200-240V Single Phase +10% -15% at 50-60Hz
Short Circuit Rating: 5kA. Where supply transformer exceeds 600kVA, 3% Impedance AC Line Chokes are required.
30A Fast Acting Fuses or 30A MCCB are required (Operation must be fast enough to ensure Short Circuit rating is not exceeded)
EMC Filters (EMC): IEC EN61800-3 / EN61800-5-1 Class A Category C2 (Industrial and restricted Domestic). Can be disabled if required
Mounting: Cubicle mount via 4 x M6 holes on 115 mm x 315mm centres.
Ambient: Rated 40°C.
Heat Loss at max output: [not specified]
Manufacturer Part Number: E510-203-SH1FN4S, also known as 11-301-21-203-36S. Replaces: E510-203-H1FN4S