TEC Electric IE2 1.5kW (3HP) 112 8P Vector Motor 230/400V B3 FVU ENC

1.583TECAB3-1PHFVU-2048ENCODER (TECA2-112-8-B3 FVU Enc 2048)

Order Code: 35061
Obsolete Product
This item is now obsolete. Alternatives may be available - see linked products below.

Brand: TEC Electric Motors, Range: TECA Three Phase IE2 Aluminium

TEC Electric 1.5kW 3ph 8 Pole High Efficiency Foot Mounting (B3) 112 Frame AC Motor for 230V or 400V 3 phase supply. Inverter Rated for use with a Variable Frequency Inverter Drive having 1ph or 3ph input and 3ph output. 
Complete with 2048ppr Encoder (fitted with a plug and socket) and Axial Force Ventilation Fan 1ph 240v

Fixed mains supply output: 1.5kW (2HP) x 710RPM at 230V or 400V x 50Hz 3ph.
Inverter Supply Output: 20:1 Speed Control range from 71RPM to 994RPM for 5Hz to 70Hz control, with suitable de-rating at the lower speeds.

Force vent unit Single phase 240V 50Hz 0.175A 85W 2600rpm 

Full Load Current - 4.3A at 400V. and 7.45A at 240V
Power Factor is 0.75 when mains connected at 50Hz.
Efficiency is 75%

250mm Wide x 397mm Long x 279mm high overall in its IP55 enclosure. (FVU not included, possible inclusion of an exstension to cater for the encoder)
Foot mount on 12mm holes at 190mm wide x 140mm centres 70mm back from the shaft shoulder. 
Shaft is 28mm dia x 60mm with 8mm wide key.
Weight is 26kg.

Rated at 40C Ambient.
Ventilation space required at rear cooling air intake.
Thermistor for over-temperature protection.
Part number is - 1.53TECAB3-IE2-FVU-ENC/2048 PLUG/SOCKET

For Variable Speed use:-
Part Time Output when Inverter powered is...
10.1 Nm - 1.5kW ( 2HP) x 1410 RPM at 100 Hz
20.2 Nm - 1.5kW ( 2HP) x 710 RPM at 50 Hz
20.2 Nm - 0.75kW ( 1HP) x 355 RPM at 25 Hz
20.2 Nm - 0.08kW (0.29HP) x 71 RPM at 5 Hz
Continuous Output when Inverter powered is...
14.4 Nm - 1.5kW ( 2.95HP) x 994 RPM at 70 Hz
20.18 Nm - 1.5kW ( 2HP) x 710 RPM at 50 Hz
14.9 Nm - 0.75 kW ( 1HP) x 355 RPM at 25 Hz
6.72 Nm - 0.15kW (0.2HP) x 71 RPM at 5 Hz

Download the full Manual and Dimensions from the links below:-

From Jan 1st 2017, three phase electric induction motors with a rated output of 0.75kW to 375kW and efficiency less than IE3 must be equipped with a variable speed drive (Inverter Drive). For exceptions, see EC Commission Regulation 640/2009.