HowTo: ACS150 fitted to Technogym Run 600 XP Pro Treadmill to replace Hitachi's SJ100-015NFE

A drive from our stock was supplied on a same day delivery for a Technogym Run 600 XP Treadmill. The original Hitachi SJ100-015NFE had failed, after providing excellent service and was replaced by Dean Wright of Telford.

The replacement drive was an ACS150 rated at 1.5kW. This is a general purpose Inverter Drive, used for many applications including; small machine tools, conveyers, energy saving fans and pumps, small hoists, turntables, food processing machines and many other applications in all areas of Industry.

The Hitachi Inverter has a number of settings changed from the default values. They are as follows:-

Parameter Desc Value
F6 Ramp up time set to 15 seconds
F7 Ramp down time set to 15 seconds
A0 starting torque Set to 2 for high
A1 motor rating in kW Set to 1
A26   Set to 1.5 so the drive turns off when the setpoint is below 1.5Hz
A27 max speed for the setpoint Set to 97
A42 disable reverse rotation Set to 0
A48 0/10V analogue input Set to 1
A63 Max frequency Set to 98
C0  external trip function on one of the terminals Set to 09
C20 relay contact function (Fault or Healthy?) set to 01

 If you know what the equavalent ACS150 settings are, let us know and we will add your information.